Build core knowledge for required respirator use. For workers in general industry and construction. Examples use devices that fit tightly to the face and filter the air. Work in IDLH air is outside this core. Your employer must add the actual task instruction, medical review, fit test and safe-use check. This course does not qualify you to lead a program, run a fit test, use supplied air, fight fires or perform rescue.
Lesson 1
Start with the air and the work
A worker is about to grind a coated part. The dust collector is down. A box of respirators sits nearby. The box does not make the task ready. The team must review the air hazard, restore needed controls and confirm the work plan.
A respirator is a device that helps protect you from a specific breathing hazard. It works only when it suits the hazard and is used in the right way. Poor fit, wrong use or poor care can let harmful air reach you.
The employer must use feasible engineering controls to limit airborne harm. These can include enclosure, local exhaust or a safer material. Respirators are needed when suitable controls are not feasible, while controls are being put in place, or when the rules otherwise require them. They do not cancel other required controls.
The employer runs a written program for required use. A program administrator oversees it. Ask who that person is and how to reach them. The employer provides required respirators, training and medical evaluations at no cost to you.
Basis: 1910.134(a), (c)(1), (c)(3)–(4), (k)(1)(i), (vii); 1926.103.
Lesson 2
Match protection to the actual hazard
The same task can release dust, gas, vapor or a mix. A qualified exposure review must identify the hazard and estimate the exposure. The employer then selects a respirator for that work and that person. You do not choose a device by its color, price or comfort alone.
An N95 filtering facepiece is designed for certain particles. It does not protect against gases or vapors. A device that filters air does not add oxygen. A high filter rating does not make it suitable for every task.
Use the exact approved facepiece and the right filters or cartridges. NIOSH approves respirators as specified systems. Parts that look alike may not be approved together. Keep labels legible. Do not mix brands or make changes without the program’s review.
The employer must also check the level of protection, the expected exposure and the device’s limits. A filter-efficiency number alone does not show how much protection the whole system provides in use.
Basis: 1910.134(d)(1)–(3), (j), (k)(1)(ii).
Lesson 3
Complete the medical step first
Respirator use can make breathing and work harder. A doctor or another licensed health care professional checks whether you can use it. The rule calls that person the PLHCP. The review must happen before a fit test or required use.
The employer arranges the review at no cost to you. The PLHCP uses the required medical questionnaire or an exam that gets the same information. Follow-up may be needed. The employer must give the PLHCP details about the work and the planned equipment.
Answer medical questions through the private medical process. Do not put diagnoses or completed questionnaires in the course, a discussion post or an ordinary training log. You must have a chance to discuss the questionnaire and results with the PLHCP. The process must be private and understandable.
The employer receives the permitted written recommendation, including limits on use and any need for follow-up. A quiz score is not that recommendation. You receive a copy of the written recommendation. Follow its limits. Do not start use while the required review is missing.
New symptoms or a change in work burden may call for another medical review. There is no single OSHA rule that renews every medical evaluation each year. Annual training and annual tight-facepiece fit testing are separate duties.
Basis: 1910.134(e), (k)(1)(vi), (m)(1).
Lesson 4
Use the facepiece that was fit tested
A tight-fitting facepiece must seal to your face. Before required use, you must pass an accepted fit test for the same make, model, style and size that you will use. A different size or model needs a new test. Required tight-fitting facepieces need testing at least once a year.
A fit test uses an OSHA-accepted method. The tester must use the right method for the equipment and required protection. A short online exercise or a signed receipt cannot replace it. This course does not train you to run a fit test.
Tell the program administrator if changes could affect fit. Examples include facial scarring, dental work or a clear change in body weight. Another fit test may be needed before use. Report a facepiece that no longer feels acceptable even if the last test passed.
A user seal check is different. You perform that check each time you put on a tight-fitting respirator. It helps find a poor seal at that moment. It does not replace the formal fit test. A fit test does not replace the seal check.
Basis: 1910.134(f), (k)(1)(iv), (m)(2); Appendix A.
Lesson 5
Keep the face seal clear
A good fit test can be defeated by a poor seal during the job. Hair between the sealing surface and your face, or hair that affects a valve, is not allowed with required tight-fitting use. Other conditions that interfere with the seal or a valve must also be resolved.
Glasses, goggles, hard hats and other gear must work with the facepiece. Do not tuck a strap or cloth under the seal. Do not change the device to make other gear fit. Ask for a suitable setup.
Each time you put it on, follow the approved method taught for your exact model. Perform the user seal check in Appendix B-1, or an equally effective manufacturer method accepted by the employer. The steps depend on the device. A glance in a mirror is not the check.
If the check fails, stay out of the hazardous area. Follow the taught adjustment steps and repeat the check. If you cannot get a sound seal, report it and obtain a suitable solution before use. Never loosen the facepiece in harmful air just to improve comfort.
Basis: 1910.134(g)(1), (k)(1)(iv); Appendix B-1.
Lesson 6
Check the equipment before use
Inspect routine-use respirators before each use and during cleaning. Learn the checks for your model. Check its function, connections and parts. These may include the facepiece, straps, valves, tubes, filters and cartridges. Flexible parts must remain in good condition.
Look for cracks, missing or dirty valves, damaged straps, loose connections and other faults in the model’s instructions. Check the filter or cartridge identity and label. Follow the actual service-life and replacement plan. A device can look clean and still be unsuitable.
Take a failed or defective device out of service. Use the employer’s report and replacement route. Do not cut, glue or tape a part to make it last. Only people trained for the work may make allowed repairs, using the right approved parts and the manufacturer’s limits.
Emergency and escape devices have extra inspection duties. They are not made ready by a routine worker check alone. Their use and inspection need a separate task program outside this core.
Basis: 1910.134(h)(3)–(4), (j), (k)(1)(iv).
Lesson 7
Practice putting it on, using it and taking it off
Read the model’s instructions with your trainer. Practice in a safe, clean place with the actual approved equipment. The trainer must see that you can inspect it, put it on, adjust it, perform the seal check, use it and take it off in the right way.
Before entry, confirm the task, air hazards, controls, work limits and exit route. Make sure needed filters and replacement parts are ready. Use the exact facepiece covered by your fit test when a tight fit is required. Follow all medical-use limits.
Keep the respirator in place while you are in air that requires it. Do not lift it to talk, scratch your face or change a cartridge. Leave by the safe route before removal, cleaning or replacement. The plan must allow safe breaks and communication.
Follow the actual doffing and hygiene method in the clean area. Avoid spreading contamination to your face, hands, clothes or clean equipment. This course does not teach a special infectious-agent or chemical decontamination procedure.
Basis: 1910.134(g)(1)–(2), (k)(1)(iv).
Lesson 8
Follow the filter and cartridge plan
A filter used for particles is not a cartridge for a gas or vapor. A cartridge for one chemical may not protect against another. Use the exact element approved in the employer’s plan for the assessed task. Check the label and compatible system parts.
For gas and vapor cartridges, the employer must use a suitable NIOSH-certified end-of-service-life indicator or a change schedule based on objective information or data. That plan must change the cartridge before its service life ends. Your nose is not a reliable change schedule.
The schedule depends on real conditions. A new material, longer use, heavier work or a change in the air can call for review. Do not extend the schedule because a cartridge looks unused. Do not assume one shift is right for every product.
Follow the manufacturer’s instructions and the employer’s criteria for replacing particle filters. If resistance changes, the seal leaks or gas or vapor breaks through, leave the use area as trained. Have protection corrected before return. Replace elements in a safe area.
Basis: 1910.134(d)(3)(iii)–(iv), (g)(2), (j).
Lesson 9
Clean, store and maintain the right way
The employer must provide gear that is clean and works well. Cleaning removes dirt. Disinfecting reduces germs. Use Appendix B-2 or the maker’s method. The maker’s method is an option only if it is equally effective and accepted by the employer. Learn which parts can be cleaned and which must be replaced.
Your own reusable respirator needs cleaning and disinfection as often as needed to keep it sanitary. Shared gear needs both steps before a different person wears it. Gear used for fit tests or training needs both steps after each use.
Do not wash a disposable filtering facepiece or a filter unless the maker’s instructions allow it. Water or chemicals can harm it. A clean look does not prove safe performance.
Store it away from damage and dirt. Protect it from sunlight, extreme heat or cold, too much moisture and harmful chemicals. Do not crush the facepiece or valves. Follow the exact model’s storage instructions. An open workbench or dirty locker may not protect it.
Basis: 1910.134(h)(1)–(4), (k)(1)(v); Appendix B-2.
Lesson 10
Leave safely when protection fails
Before work, learn the employer’s alarm, exit, help and emergency procedures. Know what you must do if protection fails or the air changes. The plan must fit the actual place and task. A generic lesson cannot supply a site’s safe escape route.
Leave the respirator use area if you detect gas or vapor breakthrough, a change in breathing resistance or facepiece leakage. Keep the device on while you reach safe air, as the actual emergency procedure directs. Do not take it off in harmful air to check the problem.
Report the condition and get the equipment repaired or replaced before return. The employer must review a change that could affect protection. A new cloud, material, process or failed control can make the prior selection wrong.
Unknown exposure and IDLH conditions need specialized selection, controls and rescue arrangements. Filters do not add oxygen. This core does not qualify you for IDLH entry, supplied-air work, confined-space rescue or interior structural firefighting.
Basis: 1910.134(d)(1)(iii), (g)(2)–(4), (k)(1)(iii).
Lesson 11
Report health signs and changes
Watch for signs that respirator use may not be safe for you. These can include hard breathing, dizziness, chest discomfort, faintness or distress. Follow the safe exit and emergency plan. Get help when needed. Do not use the quiz or a coworker’s guess to diagnose the cause.
The employer must arrange more medical review when you report related signs or symptoms. The PLHCP or other people named by the rule may also call for it. Program checks may show a need, too. A change that makes the work burden greater can create another need for review.
Examples are a heavier task, more time wearing the device, added protective clothing or much more heat. Tell the program contact before you rely on the old plan. A different device may need a new medical decision and fit test.
Keep personal medical facts in the private health process. A supervisor needs the limits that affect work, not your completed medical questionnaire. The PLHCP decides medical limits through the proper process.
Basis: 1910.134(e)(6)–(7), (k)(1)(vi).
Lesson 12
Connect the course to the workplace
Required-use training must happen before use. It must be clear to the worker and recur each year. Retraining is also needed when changes make earlier training obsolete, when knowledge or use shows a gap, or when another situation calls for it. Do not wait for the annual date when a gap is known.
The employer may credit topics taught within the last 12 months when it can show that the new employee can demonstrate that knowledge. Credited topics still need repeat training no later than 12 months after the earlier training. Employer-specific gaps must be taught.
Your employer must connect this core to its program, actual hazards, equipment, instructions and emergency plan. It must verify the required knowledge and safe use. Ask questions and explain the actions in your own words. The administrator must consult users and correct program problems.
Keep the records separate: online knowledge; workplace instruction and demonstration; the medical process; and the actual fit test. A course pass does not fill the other records. Medical records follow their own rules. Fit-test records stay until the next fit test. The employer keeps the current written program.
Basis: 1910.134(c), (k)(1)–(6), (l), (m).
Primary sources reviewed October 21, 2026
- Federal respiratory protection — 1910.134
- Construction — 1926.103
- Fit testing — Appendix A
- User seal checks — Appendix B-1
- Cleaning — Appendix B-2
- Voluntary-use information — Appendix D
- Voluntary-use interpretation, April 26, 2018
- Filtering-facepiece medical distinction, April 24, 2018
- Online training interpretation, July 11, 2019
- State Plan directory
Use the federal rule with actual manufacturer instructions, substance-specific rules and applicable State Plan requirements. Construction 1926.103 applies identical respiratory-protection requirements; that does not remove other construction duties.
Development inputs: the current SHP-007 Respiratory Protection Program approved development template (Library version 1); RAVS_Requirements (46).pdf, exported July 22, 2022, nine questions; and training inventory TR-008. Template approval and historical contractor review results are not course validation, current client acceptance or employer authorization. Historical employer names, responses and approval marks are not reproduced. The questionnaire’s Cal/OSHA references require current employer-specific review; no State Plan equivalence is asserted.